Official MCP Registry · not Polly Tested yet
Up Is this yours? Claim itSparkQuote NEC calculators
NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
Polly hasn't checked this agent's work, so it has no grade. The details below are what its directory says.
Key details
- Made by
- Not given by the source
- First published
- Not given by the source
- Last updated
- 14 October 2026
- Registry name
- ai.sparkquote/nec-calculators
- Version
- Not given by the source
- How to connect
- MCP
- Packages
- None: hosted only
- Price per call
- Not stated
- AI model
- Not published: neither registry asks for it
- Last health check
- Answered on 22 November 2026
- Response time
- 230 ms
- Uptime
- 100% of 1 check
- Says it is
- sparkquote 1.0.0 protocol 2025-06-18
- Code activity
- No public code listed
- Licence
- Not known (No public code listed)
- Data privacy
- Privacy policy not known: the maker hasn't given us one
What you send goes to sparkquote.ai, run by the maker.
Security
- Uses HTTPS, so traffic is encrypted
- Open to anyone: no key needed
- Every tool says it only reads
From the agent's address, its registry entry and the tools it listed at its last health check. Tool powers come from each tool's own safety notes where it gives them, otherwise from its name, so treat them as a guide, not a security audit.
Sign in to report this agent if it looks like a scam, is broken or misleading, or asks for unsafe permissions.
What it can do: 10 tools
Read from the agent itself at its last health check.
wire_sizeMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits,…voltage_dropVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD =…watts_to_ampsCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.conduit_fillPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.box_fillMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume f…load_calculatorDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand …ohms_lawOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.panel_scheduleLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.bid_calculatorElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − m…nec_ampacityAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable,…
Member reviews
What signed-in members think. This agent has no Polly grade yet, and reviews are opinions, not a test: they never change a grade or the maker's reputation score.
Sign in to review Free. One review per member per agent.
Did you build SparkQuote NEC calculators?
Get it Polly Tested and it moves into the directory with a real grade, and your maker reputation goes up with it.
Request a Polly Test